Search results for " DETECTOR."
showing 10 items of 2685 documents
Formation of dislocations and hardening of LiF under high-dose irradiation with 5–21 MeV 12C ions
2017
R. Zabels, I. Manika, J. Maniks, and R.Grants acknowledge the national project IMIS2, and A. Dauletbekova, M. Baizhumanov, and M. Zdorovets the Ministry of Education and Science of the Republic of Kazakhstan for the financial support.
Systematic and statistical uncertainties of the hilbert-transform based high-precision FID frequency extraction method.
2021
Abstract Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is one of the methods that have been used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described, and it is briefly compared with other commonly used frequency extraction methods. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytical…
Photoelectron Emission from Metal Surfaces Induced by VUV-emission of Filament Driven Hydrogen Arc Discharge Plasma
2015
Photoelectron emission measurements have been performed using a filament-driven multi-cusp arc discharge volume production H^- ion source (LIISA). It has been found that photoelectron currents obtained with Al, Cu, Mo, Ta and stainless steel (SAE 304) are on the same order of magnitude. The photoelectron currents depend linearly on the discharge power. It is shown experimentally that photoelectron emission is significant only in the short wavelength range of hydrogen spectrum due to the energy dependence of the quantum efficiency. It is estimated from the measured data that the maximum photoelectron flux from plasma chamber walls is on the order of 1 A per kW of discharge power.
Optimization of a laser ion source for $^{163}$Ho isotope separation
2019
To measure the mass of the electron neutrino, the “Electron Capture in Holmium-163” (ECHo) collaboration aims at calorimetrically measuring the spectrum following electron capture in 163Ho. The success of the ECHo experiment depends critically on the radiochemical purity of the 163Ho sample, which is ion-implanted into the calorimeters. For this, a 30 kV high transmission magnetic mass separator equipped with a resonance ionization laser ion source is used. To meet the ECHo requirements, the ion source unit was optimized with respect to its thermal characteristics and material composition by means of the finite element method thermal-electric calculations and chemical equilibrium simulation…
Photoelectron Emission from Metal Surfaces Induced by Radiation Emitted by a 14 GHz Electron Cyclotron Resonance Ion Source
2015
Photoelectron emission measurements have been performed using a room-temperature 14 GHz ECR ion source. It is shown that the photoelectron emission from Al, Cu, and stainless steel (SAE 304) surfaces, which are common plasma chamber materials, is predominantly caused by radiation emitted from plasma with energies between 8 eV and 1 keV. Characteristic X-ray emission and bremsstrahlung from plasma have a negligible contribution to the photoelectron emission. It is estimated from the measured data that the maximum conceivable photoelectron flux from plasma chamber walls is on the order of 10% of the estimated total electron losses from the plasma. peerReviewed
Conceptual study of a heavy-ion-ERDA spectrometer for energies below 6 MeV
2017
Abstract Elastic recoil detection analysis (ERDA) is a well established technique and it offers unique capabilities in thin film analysis. Simultaneous detection and depth profiling of all elements, including hydrogen, is possible only with time-of-flight ERDA. Bragg ionization chambers or Δ E - E detectors can also be used to identify the recoiling element if sufficiently high energies are used. The chief limitations of time-of-flight ERDA are the beam induced sample damage and the requirement of a relatively large accelerator. In this paper we propose a detector setup, which could be used with 3 MeV to 6 MeV medium heavy beams from either a single ended accelerator (40Ar) or from a tandem…
Comparison of the F-type center thermal annealing in heavy-ion and neutron irradiated Al2O3 single crystals
2018
Abstract The optical absorption and thermally stimulated luminescence of Al2O3 (sapphire) single crystals irradiated with swift heavy ions (SHI) 238U with energy 2.4 GeV is studied with the focus on the thermal annealing of the F-type centers in a wide temperature range of 400–1500 K. Its theoretical analysis allows us to obtain activation energies and pre-exponentials of the interstitial oxygen ion migration, which recombine with both types of immobile electron centers (F and F+ centers). A comparison of these kinetics parameters with literature data for a neutron-irradiated sapphire shows their similarity and thus supports the use of SHI-irradiation for modeling the neutron irradiation.
Thermal annealing of radiation damage produced by swift 132Xe ions in MgO single crystals
2020
Abstract The annealing kinetics of the electron-type F+ and F color centers in highly pure MgO single crystals irradiated by 0.23-GeV 132Xe ions with fluences covering three orders of magnitude (Φ = 5 × 1011 –3.3 × 1014 ions/cm2) are studied experimentally via dependence of the optical absorption on preheating temperature. The annealing data are analyzed in terms of the diffusion-controlled bimolecular reactions between F-type centers and complementary interstitial oxygen ions. The behavior of the main kinetic parameters – the migration energies and pre-exponential factors – for different irradiation fluences is discussed and compared with that for other wide-gap binary materials from previ…
Commissioning of the vacuum system of the KATRIN Main Spectrometer
2016
The KATRIN experiment will probe the neutrino mass by measuring the β-electron energy spectrum near the endpoint of tritium β-decay. An integral energy analysis will be performed by an electro-static spectrometer (``Main Spectrometer''), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m[superscript 3], and a complex inner electrode system with about 120 000 individual parts. The strong magnetic field that guides the β-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips ha…
Radiation hardness studies of CdTe and for the SIXS particle detector on-board the BepiColombo spacecraft
2009
Abstract We report of the radiation hardness measurements that were performed in the developing work of a particle detector on-board ESA's forthcoming BepiColombo spacecraft. Two different high- Z semiconductor compounds, cadmium telluride (CdTe) and mercuric iodide (HgI 2 ), were irradiated with 22 MeV protons in four steps to attain the estimated total dose of 10 12 p / cm 2 for the mission time. The performance of the detectors was studied before and after every irradiation with radioactive 55 Fe source Mn K α 5.9 keV emission line. We studied the impact of the proton beam exposure on detector leakage current, energy resolution and charge collection efficiency (CCE). Also the reconstruct…